The RUD ABA Lifting Point For Welding has a safety rating of 4:1 and comes fully tested and approved by DGUV. The ABA lifting point can be used in some pretty harsh conditions in temperatures that range from -40˚C up to 200˚C with a maximum temperature of 400˚C (please allow up to 25% loss in WLL when operating at maximum temperature). The ABA lifting point has patented markings on each point for easy determination for withdraw of service.
RUD_ABA_Safety_Instructions.pdf ⬇ |
Model | Product Code | Weight (kg) | Nominal WLL (kg) | T (mm) | A (mm) | B (mm) | C (mm) | D (mm) | E (mm) | F (mm) |
---|---|---|---|---|---|---|---|---|---|---|
ABA1.6t | 7900352 | 0.45 | 1600kg | 42 | 30 | 16 | 100 | 35 | 16 | 57 |
ABA3.2t | 7900353 | 1.15 | 3200kg | 59 | 41 | 23 | 137 | 50 | 21 | 80 |
ABA5.0t | 7900354 | 2.26 | 5000kg | 72 | 51 | 27 | 172 | 60 | 28 | 99 |
ABA10t | 7900355 | 5.37 | 10,000kg | 95 | 70 | 38 | 228 | 80 | 35 | 130 |
ABA20t | 7902174 | 10.72 | 20,000kg | 135 | 90 | 52 | 272 | 115 | 40 | 175 |
ABA31.5t | 7902175 | 18.33 | 31,500kg | 154 | 108 | 64 | 320 | 130 | 50 | 204 |